Counts – 50,000 and 5000 (selectable).
Digits – 4-4/5 and 3-4/5 (selectable).
Update Rate – 4/s (5000 count mode), 1/s (50,000 count mode).
20 Segment Analog Bar Graph
Update Rate – 20/s.
Nonvolatile Memory
Locations – 30 (TX3); 10 (TX1).
Peak Hold
1 ms.
DC/AC Voltage
Ranges*1 – 500.0 mV, 5.000 V, 50.00 V, 500.0 V, 1000 V CAT III.
DC Accuracy*1 – ±(0.05% + 1 ct.) (TX3), ±(0.07% + 1 ct.) (TX1).
AC Accuracy*1 – ±(0.4% + 2 ct.) (TX3), ±(0.6% + 2 ct.) (TX1).
Best Resolution – 10 µV (50,000 ct. mode).
DC/AC Current
Ranges*1 – 500.0 µA, 5.000 mA, 50.00 mA, 500.0 mA, 5.000 A, 10.00 A (continuous), 15 A (30 seconds).
DC Accuracy*1 – ±(0.2% + 2 ct.).
AC Accuracy*1 – ±(0.6% + 2 ct.).
Best Resolution – 10 nA (50,000 ct. mode).
Resistance
Ranges*1 – 50.00 Ohm, 500.0 Ohm, 5.000 kilohm, 50.00 kilohm, 500.0 kilohm, 5.000 megaohm, 50.00 megaohm.
Accuracy*1 – ±(0.1% + 2 ct.).
Best Resolution – 0.01 Ohm (in 50 Ohm range w/automatic lead calibration).
Capacitance
Ranges – 5.000 nF, 50.00 nF, 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF, 5.000 mF, 50.00 mF.
Best Accuracy*1 – ±(1.0% + 3 ct.).
Best Resolution – 1 pF.
Frequency
Range – 0.5 Hz to 1 MHz.
Accuracy*1 – ±(0.002% + 1 ct.).
Best Resolution – 0.001 Hz.
Counter – 5-digit; 100,000 count.
Temperature (TX3 Only)
Built-in Digital Thermometer – K-type Thermocouple.
Range – -50°C to +980°C (not including thermocouple range).
Accuracy*1 – ±3°C typical, ±1°C with quick ice bath calibration.
Safety – UL3111-1, CSA1010.1, EN61010-1.