Application

FM approved for hazardous environments, the explosion proof ultrasonic level transmitter provides continuous level measurement up to 32.8' (10m) with a 4-20 mA signal output, and is configured via the integral push button display module. This non-contact liquid level sensor is ideally suited for corrosive, ultrapure, sticky or dirty liquids, and is widely selected for bulk storage, day tank, lift station and process tank level applications located in a classified area.

Features

Explosion proof level transmitter for use in hazardous areas

Offered in 2 measurement ranges from 26.2' (8m) to 32.8? (10m)

Configuration is simple via integral push button display module

Type 4 aluminum XP windowed enclosure with dual conduit ports

LCD display indicates level in inches, centimeters or percent of span

Narrow 3" beam width for applications with limited measurement space

Rugged PVDF transducer and process mounting plug for corrosive liquids

Automatic temperature compensation for accurate measurement

– See more at: http://www.flowline.com/echosafe.php#sthash.zncN2esz.dpuf

Application:
FM approved for hazardous environments, the explosion proof ultrasonic level transmitter provides continuous level measurement up to 32.8' (10m) with a 4-20 mA signal output, and is configured via the integral push button display module. This non-contact liquid level sensor is ideally suited for corrosive, ultrapure, sticky or dirty liquids, and is widely selected for bulk storage, day tank, lift station and process tank level applications located in a classified area.
Features:

Explosion proof level transmitter for use in hazardous areas

Offered in 2 measurement ranges from 26.2' (8m) to 32.8? (10m)

Configuration is simple via integral push button display module

Type 4 aluminum XP windowed enclosure with dual conduit ports

LCD display indicates level in inches, centimeters or percent of span

Narrow 3" beam width for applications with limited measurement space

Rugged PVDF transducer and process mounting plug for corrosive liquids

Automatic temperature compensation for accurate measurement

Specifications

Range: XP88: 8" to 26.2' (20cm to 8m)
XP89: 8" to 32.8' (20cm to 10m)
Accuracy: ± 0.2% of range
Resolution: 0.079" (2mm)
Dead band: 8" (20cm)
Beam width: 3" (7.6cm)
Configuration: Push button
Memory: Non-volatile
Display type: LCD, 6-digit
Display units: Inch, cm, percent, feet or meter
Supply voltage: 18-28 VDC (loop)
Loop resist.: 250 Ohms max @ 24 VDC
Signal output: 4-20 mA, two-wire
Signal invert: 4-20 mA or 20-4 mA
Signal fail-safe: 4 mA, 20mA, 21 mA, 22 mA
or hold last
Process temp.: F: -4° to 140°
C: -20° to 60°
Temp. comp.: Automatic
Ambient temp.: F: -4° to 140°
C: -20° to 60°
Pressure: MWP = 30 psi (2 bar)
Enclosure rating: Type 4
Encl. material: Aluminum
Window material: Glass
Conduit entrance: Dual, 1/2" NPT
Trans. material: PVDF
Process mount: 2" NPT
Mount gasket: Viton®
Classification: Explosion proof
Compliance: CE, RoHS
Approvals: FM: Class I, Div I
Groups A, B, C, D
Class II/III, Div I,
Groups E, F, G

– See more at: http://www.flowline.com/echosafe.php#sthash.zncN2esz.dpuf

Specifications:
Range:     XP88: 8" to 26.2' (20cm to 8m)
XP89: 8" to 32.8' (20cm to 10m)
Accuracy:     ± 0.2% of range
Resolution:     0.079" (2mm)
Dead band:     8" (20cm)
Beam width:     3" (7.6cm)
Configuration:     Push button
Memory:     Non-volatile
Display type:     LCD, 6-digit
Display units:     Inch, cm, percent, feet or meter
Supply voltage:     18-28 VDC (loop)
Loop resist.:     250 Ohms max @ 24 VDC
Signal output:     4-20 mA, two-wire
Signal invert:     4-20 mA or 20-4 mA
Signal fail-safe:     4 mA, 20mA, 21 mA, 22 mA
or hold last
Process temp.:     F: -4° to 140°
C: -20° to 60°
Temp. comp.:     Automatic
Ambient temp.:     F: -4° to 140°
C: -20° to 60°
Pressure:     MWP = 30 psi (2 bar)
Enclosure rating:     Type 4
Encl. material:     Aluminum
Window material:     Glass
Conduit entrance:     Dual, 1/2" NPT
Trans. material:     PVDF
Process mount:     2" NPT
Mount gasket:     Viton®
Classification:     Explosion proof
Compliance:     CE, RoHS
Approvals:     FM: Class I, Div I
Groups A, B, C, D
Class II/III, Div I,
Groups E, F, G