Temperature Measurement of Liquid Metals
Cyclops 055B Meltmaster is a dedicated high precision, portable infrared thermometer, designed for accurate measurement of liquid metal temperatures in the range 1000 to 2000 °C / 1832 to 3632 °F.
The measured temperature is displayed in four simultaneous modes including the new, advanced ‘Meltmaster’ mode.
Accurate sighting is ensured by the clear, wide angle (9°) field of view and small, clearly defined (1/3°) measurement area. Focusing is fixed at 5m / 16ft.
Emissivity compensation is provided via the icon-based menu system.
The operating waveband has been carefully chosen to minimise errors due to uncertainty in emissivity and the effects of atmospheric vapour components.
Significantly reduces the use and cost of disposable ‘dip’ type thermocouples.
The operating waveband has been carefully chosen to minimise errors due to uncertainty in emissivity and the effects of atmospheric vapour components.
Key Features
High accuracy liquid metal temperature measurement | No contamination, interference or damage to process or material |
Unique 'Meltmaster' measurement mode | Confidencet in the measurement for process control and quality control applications |
Non-contact measurement method | Reduce the number of expensive dip thermocouple readings that you take |
One-handed operation, contact free measurement | Bettr safety in hazardous locations |
High accuracy and repeatability | Confidence in the measurement for process control applications |
Long term, drift free measurement | Confidence in the measurement |
Standard Bluetooth® | No twisted or broken cables, link straight to a PDA device |
Rugged instrument casing | Can withstand harsh environments for extended periods |
Calibrated and traceable to National Standards | Your guarantee of measurement accuracy |
Four Measurement modes – Meltmaster, Continuous, Peak and Valley | Measurement to exactly meet your own specific requirements |
Innovative advanced spectral filtering | Enhance instrument performance |
Digital signal processing, output for data logging | Access your measurement information and record it |
Range of optional accessories – including a DL-1000 Data Logger, Long Eye Relief piece adapter, Rugged IP67 PDA, Heat resistant jacket, Waterproof carry case | Customise to your measurement needs |
Ideal for Liquid Metal Temperature Measurement
The unique features of the Cyclops Meltmaster portable infrared thermometer make it the ideal instrument for accurate non contact temperature measurements of liquid metals in the foundry.Measuring the temperature of molten metal in a foundry can be a slow and disruptive process. The use of disposable dip thermocouples can be both expensive and hazardous. The NEW Meltmaster is both fast and accurate, easy to use, and does not contact the liquid metal. Cyclops Meltmaster is intended to save time and money in the foundry by reducing the number of dips required with disposable thermocouples.
Meltmaster Measuring mode
The measured temperature is displayed in four simultaneous modes including the new, advanced "Meltmaster" mode.
Accurate sighting is ensured by the clear, wide angle (9°) field of view and small, clearly defined (1/3°) measurement area. Focusing is fixed at 5 m / 16 ft.
Emissivity compensation is provided via the icon-based menu system. The operating waveband has been carefully chosen to minimise errors due to uncertainty in emissivity and the effects of atmospheric vapour components.
The Cyclops 055B features standard Bluetooth® wireless technology enabled. Ergonomic design allows easy, onehanded operation in hostile environments.Significantly reduces the use and cost of disposable "dip" type thermocouples.
Optics
Through the lens reflex optical system gives a precise definition of the target spot and simultaneous backlit display of user selected values in the viewfinder.
Multifunction Display The bright, back-lit external display panel provides an indication of status and configuration of the thermometer together with four simultaneous live measurement modes. The panel displays a simple icon-driven, language-free menu system navigated via keypad controls.
- Mode selection
- Emissivity
- Window Compensation
- Communication Status
- Battery Status
- Alarm Status
The user highlights the mode to be displayed in the viewfinder.
Menu Controls
Simple, easy to use controls to select required mode from the icon based menu.
Trigger
Robust trigger to take and store temperature readings.
Connectivity
055B model offers data logging to optional DL-1000 Datalogger
Temperatures | |||
---|---|---|---|
Low Temperature (C): | 1000 | High Temperature (C): | 2000 |
Low Temperature (F): | 1832 | High Temperature (F): | 3632 |
Technical Details
Measurement range: | 1000 to 2000 °C/1830 to 3632 °F |
Indication: | 4-digit LCD in viewfinder; external backlit LCD display |
Measuring Modes: | Peak, Continuous, Valley and advanced MeltMaster processing functions |
Data Logging: | To iPAQ or laptop/PC running DL-1000v2 software. Wiireless connection via Bluetooth® wireless technology |
Optical System: | 9° field of view; 1/3° measurement area Output: (180:1 to 98 % energy); eyepiece adjustable 3.75 to +2.5 diopters |
Focusing Range: | Fixed Focus, nominally at 5 m / 197 in. from thermometer body datum |
Target Size: | Nominally a constant 28 mm / 1.1 in target spot diameter from lens to 5 m / 197 in. |
Spectral Response: | Nominally 0.55 µm |
Emissivity adjustment: | 0.10 to 1.20 in 0.01 step graduations |
Response time: | 30 ms |
Display Update Time: | 0.5 s |
Accuracy: | <0.5 %(K) of reading |
Repeatability: | <1 °C / 2 °F |
Operating Temp. Range: | 0 to 50 °C / 32 to 122 °F |
Power Requirement: | One MN1604/6LR61/PP3 battery |
Output: | Bluetooth® wireless technology |
Dimensions: | 208x70x154mm/8.2X2.75X6.1 in |
Weight: | 0.8kg / 1.8 lb |
Sealing: | IP51 |
Standard Accessories: | Lens cap, protection window/filter, battery, wrist strap, heat protection jacket |
Optional Accessories: | Data Logger DL-1000, HP iPAQ, rugged waterproof carry case, long eye relief (LER) eyepiece |
Application
- Metal foundries
Resource & Download
Product Data Sheet – Deutsch – Sept 2011 | Download File (1.33 MB) |
|||
Product Data Sheet – Italian – Sept 2011 | Download File (557 KB) |
|||
Cyclops 055B Latin Spanish Sept 2011 | Download File (609 KB) |
|||
Cyclops 055B Meltmaster Portuguese Sept 2011 | Download File (916 KB) |
|||
Cyclops 055B French | Download File (1.34 MB) |
|||
Cyclops 055B Chinese | Download File (1.5 MB) |
|||
Cyclops 055B Spanish | Download File (4.6 MB) |
|||
Cyclops 055B Russian | Download File (1.36 MB) |
|||
Cyclops 055B Korean | Download File (1.51 MB) |
|||
Cyclops 055B User Guide | Download File (1.7 MB) |
|||
Cyclops 055 B Meltmaster for liquid metals | Download File (654 KB) |
|||
Cyclops 055B Quick Start Guide (806452) | Download File (1.68 MB) |